Typical circuits
- Chilled-water supply and return
- Hot-water and heat-recovery circuits
- Glycol circuits
- Heat-exchanger and cooling-equipment branches
SOLUTION · FLOW CONTROL
Use GRUNER valves and actuators for project-specific control of chilled water, hot water, glycol and heat-exchange circuits.
DIRECT ANSWER
Media, size, pressure, torque, shut-off and control method jointly determine valve and actuator configuration. This solution turns those inputs into a reviewable equipment scope and controls interface instead of selecting by nominal size alone.
APPLICABILITY
For project-specific review of two-way butterfly valves and electric actuators in cooling circuits.
SYSTEM & BOUNDARY
Available material covers V2..ABV butterfly valves and 910, 920 and 930U actuator ranges.
Material lists DN50–800 and PN16; media and materials still require exact-model and project-condition review.
910, 920 and 930U cover different torque, running-time, control and communication configurations.
Power, control signal, position feedback, fault indication and optional bus capabilities require version confirmation.
Project boundary
This page does not replace hydraulic calculation, valve-authority analysis, control logic, equipment interlocks or mechanical design. IP, explosion protection, over-torque protection and Modbus / Profibus / HART depend on selected range and configuration.
DELIVERY
Start from design conditions and control objectives, not from a single product code.
Confirm media, temperature, design flow, differential pressure, size, pressure class, installation and environment.
Use valve torque, shut-off, running time, power and control method to frame a configuration.
Check BMS, power, panel and installation interfaces and execute functional verification using the project method.
INTERFACES
Control authority, fail position and feedback points must align with mechanical operating strategy.
Binary, analog or bus control and position, fault and status feedback depend on the actuator version.
Pump, chiller, heat exchanger and terminal-unit sequencing and protection belong to mechanical and controls design.
Voltage, consumption, circuit protection, terminals and cabling must match final actuator configuration and electrical design.
EVIDENCE
GRUNER material supports product range, manufacturing footprint and display of IATF 16949, ISO 9001 and EMAS documents. Current project names lack scope, quantity and results, so they are not presented as KIRIAST case studies.
View GRUNER capability and certificatesFAQ
No. Confirm media, temperature, flow, differential pressure, pressure class, shut-off, environment, control objective and maintainability.
No such assumption should be made. Protocol, IP, explosion protection and protective functions depend on exact range, version and configuration.
The website does not promise unconfirmed professional scope. Consultation must identify whether the consultant, mechanical designer, equipment party or another responsible party performs and reviews calculations.
This page frames solution scope and does not replace professional fire, mechanical, controls or IT design. Project configuration must be confirmed by appropriately qualified teams using current manufacturer documentation.
Project enquiry
Share media, temperature, flow, differential pressure, size, pressure class, power and control requirements.