KIDDE · CLEAN AGENT

Kidde Clean-Agent Fire Suppression

KIRIAST accepts system and spares enquiries for Kidde ECS 360 psi and Fluoro-K (ECS-500 / ADS). Specifications remain separate; configuration, supply, marine applicability, approval scope and compatibility are confirmed per project.

DOCUMENTS

System and spares enquiry scope

The ECS 360 psi and Fluoro-K documents differ in agents, cylinders, actuation and approval language. Provide an existing-system nameplate or project specification to avoid transferring values across platforms.

D1

Fluoro-K · ECS-500 / ADS

K-45-001 Rev AA (April 2023) illustrates ECS-500 and ADS components and arrangements. The ADS nitrogen-driver pressure must remain separate from the agent-cylinder pressure.

  • ECS-500: the brochure lists 500 psi agent cylinders.D1 · pp. 1
  • ADS: the brochure lists a separate 1,800 psi nitrogen driver.D1 · pp. 1
  • D1 illustrates single-zone, multi-zone and main/reserve arrangements; exact configurations need project and manufacturer review.D1 · pp. 2, 3, 8

Kidde Fire Systems · K-45-001 Rev AA · Effective April 2023 · pp. 1–12

D2

ECS 360 psi

SSK-100 (February 2018) describes the ECS 360 psi system. Agent names and approval labels printed in the brochure are not evidence of current supply or a valid certificate for a particular vessel.

  • The ECS 360 psi brochure lists HFC-227ea and 3M Novec 1230.D2 · pp. 2

Kidde Fire Systems · SSK-100 · February 2018 · pp. 1–2

Applications

Enquiries may concern spares for an existing system, equipment renewal or a project requirement. Define the protected area, existing system and vessel requirements first; general applications in a brochure do not establish marine suitability.

Selection inputs

Provide exact models, cylinder or component nameplates, quantities, existing system family, protected area and control-interface requirements. Check ECS 360 psi, ECS-500 and ADS specifications and components separately.

INTERFACES

Controls and interfaces

Release-control-unit compatibility requires Kidde and agency listing review. Detection and alarm interfaces on a vessel are a separate boundary from suppression release control; compatibility cannot be assumed.

Approvals and project conditions

Product configuration, marine applicability, approval scope and compatibility are confirmed on a project-specific basis. Check applicable models and valid documents; product literature does not replace project approval.

Page 4 of the Fluoro-K brochure mentions cylinder straps for marine applications. This is an installation instruction, not a marine approval certificate.

The manufacturer literature calls for trained, authorized distributors for design, installation, maintenance and service. This page does not claim that KIRIAST holds that authorization.

SUPPLY & SUPPORT

KIRIAST supply and support

System and spares enquiries can be organized for manufacturer-document review and supply discussions. Availability, lead time, design support and field-service scope require separate confirmation.

Technical references

Product facts on this page refer separately to the following Kidde Fire Systems documents. Publication dates identify literature versions, not current availability or approval validity.

  • D1 · Kidde Fire Systems · K-45-001 Rev AA · Effective April 2023 · pp. 1–12
  • D2 · Kidde Fire Systems · SSK-100 · February 2018 · pp. 1–2

EMAIL ENQUIRY

Review a system or spares requirement

Share the existing system, protected area, exact model and project approval needs; supply and field service are confirmed separately.